Thermo Orion Star A212 Benchtop Conductivity Meter Banner
STARA2120

Thermo Orion Star A212 Benchtop Conductivity Meter

Thermo Orion Star A212 Benchtop Conductivity Meter

Description

The Thermo Orion Star A212 benchtop conductivity meter with electrode stand is ideal for recording conductivity in the lab with Orion mini-DIN conductivity electrodes.

Features

  • Displays conductivity, TDS, salinity, resistivity and temp readings using Orion mini-DIN electrodes
  • AUTO-READ function alerts user and locks stable readings on backlit LCD screen
  • USB and RS-232 ports allow easy data transfer of up to 2000 time-stamped data points
Free Shipping on this product
List Price
$1089.00
Your Price
$925.65
Drop ships from manufacturer

Shipping Information
Return Policy
Why Buy From Fondriest?

Details

The Thermo Orion Star A212 Benchtop Conductivity Meter is the ideal choice for any lab. The informative, backlit display shows conductivity, TDS, salinity, resistivity and temperature readings along with time, date, sample ID, user ID and calibration information. For advanced users, features such as stability and averaging choices provide additional options.

Thermo Orion Star A210 series benchtop meters provide a large storage capacity for time-stamped data points, which can be conveniently uploaded to a PC through the meter's USB and RS-232 ports. Complimentary data analysis software allows users to quickly view and manipulate data. Accuracy can be ensured through the 5 selectable reading reference temperatures and a multitude of curve options.

 

  • AUTO-READ function alerts user and locks on-screen readings when stable
  • Selectable cell constant allows for use with 2- or 4-cell conductivity cells
  • Selectable reading reference temperatures of 5, 10, 15, 20 or 25 C with linear, non-linear, nLFu or EP curve options
  • Choice of practical salinity or natural sea water curves for salinity readings
  • Linear or ISO/EN 27888 curves for TDS
  • USB and RS-232 ports to upload data and update included data analysis software
  • Non-volatile memory holds up to 2000 time-stamped data points
  • Electrode arm and newly-designed probe holder to place probes into samples
  • Universal power supply or battery power option
  • Interface supports English, Spanish, French, Italian, German and Chinese languages
  • IP54-rated splashproof housing
  • 3 year meter warranty
Notable Specifications:
  • Conductivity
  • Range: 0.001 uS to 3000 mS
  • Resolution: Min 0.001 uS or 4 significant figures
  • Relative Accuracy: 0.5% reading +/-1 digit
  • Reference: 5, 10, 15, 20, 25 C (default)
  • Compensation: Linear (0.0 to 10.0 %/C)
  • Compatible Cell Constants: 0.001 to 199.9
  • Number of Calibration Points: Up to 5
  • Calibration Editing: Yes
  • Resistivity
  • Range: 2 ohm to 100 meg-ohm
  • Resolution: 2 ohm-cm
  • Relative Accuracy: 0.5% reading +/-1 digit
  • Salinity
  • Type: Practical salinity or natural sea water
  • Range: 0.01 to 80.0 ppt NaCl equivalent; 0.01 to 42 ppt practical
  • Resolution: 0.01
  • Relative Accuracy: +/-0.1
  • TDS
  • Range: 0 to 200 ppt
  • Resolution: 4 significant figures
  • Relative Accuracy: 0.5% reading +/-1 digit
  • TDS Factor Range: Linear 0.01 to 10.00
  • Temperature
  • Range: -5 to 105 C
  • Resolution: 0.1
  • Relative Accuracy: +/-0.1 C
  • Offset Calibration: 1 point
  • Datalogging
  • Number of Points: 2000 with time and date stamp
  • Log Function: Manual, ready (AUTO-READ), timed
  • Log Edit: Delete individual points, group of points or all
  • General
  • Display: Backlit LCD
  • Inputs: 8-pin mini-DIN
  • Outputs: RS-232, USB
  • Power Adapter: Universal AC, 100-240 VAC
  • Battery Power: 4 AAs, 800 hrs life
  • Environmental Requirements: 5 to 45 C and 5 to 85% relative humidity, non-condensing
  • Regulatory and Safety: CE, TUV 3-1, FCC Class A
  • IP Rating: IP54, splashproof and dustproof
  • Warranty: 36 months (from date of purchase)
What's Included:
  • (1) Thermo Orion Star A212 conductivity meter
  • (1) Electrode stand
  • (1) Universal power adapter
Image Part # Product Description Price Stock Order
Thermo Orion Star A212 Benchtop Conductivity Meter STARA2120 Orion Star A212 benchtop conductivity meter with electrode stand
$925.65
Drop ships from manufacturer
Thermo Orion Star A212 Benchtop Conductivity Meter STARA2125 Orion Star A212 benchtop conductivity meter kit with 013005MD conductivity probe, conductivity standard and electrode stand
$1155.15
Drop ships from manufacturer
Thermo Orion Star A212 Benchtop Conductivity Meter STARA2126 Orion Star A212 benchtop conductivity meter kit with 013016MD conductivity probe with flow cell, conductivity standard and electrode stand
$1200.20
Drop ships from manufacturer
Image Part # Product Description Price Stock Order
Thermo Orion Meter-Attachable Electrode Stand STARA-BEA Orion meter-attachable electrode stand, includes electrode arm, holder & meter bracket
$137.70
Drop ships from manufacturer
Thermo Orion Freestanding Weighted Base STARA-HB Orion freestanding weighted base for use with meter-attachable electrode stand
$45.73
Drop ships from manufacturer
Thermo Orion DuraProbe 4-Electrode Conductivity Cell 013005MD Orion DuraProbe 4-electrode conductivity cell, MiniDIN connector (Star), 1.5m cable
$447.95
Drop ships from manufacturer
Thermo Orion Flow-Thru 2-Electrode Conductivity Cell 013016MD Orion 2-electrode conductivity cell with glass flow cell, MiniDIN connector (Star), 1.5m cable
$589.05
In Stock
Thermo Orion 60mL Conductivity Standards 011008 Orion conductivity standard, 100 uS, (5) 60mL bottles
$85.00
Drop ships from manufacturer
Thermo Orion 60mL Conductivity Standards 011007 Orion conductivity standard, 1413 uS, (5) 60mL bottles
$85.00
Drop ships from manufacturer
Thermo Orion 60mL Conductivity Standards 011006 Orion conductivity standard, 12,900 uS, (5) 60mL bottles
$85.00
Drop ships from manufacturer
Thermo Orion Conductivity Calibration Kit 1010001 Orion conductivity calibration kit, MiniDIN connector
$358.70
Drop ships from manufacturer
Thermo Orion Stirrer Probe 096019 Orion stirrer probe with paddle
$207.40
Drop ships from manufacturer

Questions & Answers

| Ask a Question
Can I use my Thermo stirrer probe?
Yes, the Star A212 meter can be used with the Orion Star stirrer probe (part #096019) as this meter has a button to control the stirring function.

In The News

Choosing The Right Thermo Benchtop For Your Project

Thermo Scientific’s Orion Star A line is full of options for completing projects from environmental monitoring to quality control and beyond. These include benchtops like the Orion Versa Star and portables like the Orion Star A329 . Making the right selection is important for ensuring project success, but sometimes choosing a meter can be difficult. To make things a little easier, we talked with Ricki Hartwell, the global product manager for Thermo Scientific’s Orion Laboratory and Field Instruments. She gave some tips to help customers find the best meter to meet their needs. Let’s take a look at her recommendations for benchtops.

Read More

What is Conductivity?

UPDATE : Fondriest Environmental is offering their expertise in conductivity through their new online knowledge base. This resource provides an updated and comprehensive look at conductivity and why it is important to water quality. To learn more, check out: Conductivity, Salinity and TDS . Salinity and conductivity  measure the water's ability to conduct electricity, which provides a measure of what is dissolved in water. In the SWMP data, a higher conductivity value indicates that there are more chemicals dissolved in the water. Conductivity measures the water's ability to conduct electricity. It is the opposite of resistance. Pure, distilled water is a poor conductor of electricity.

Read More

Lake Michigan Yellow Perch Bounce Back After Commercial Ban

For decades, commercial fishing for yellow perch was allowed in southern Lake Michigan. This persisted until 1996 when it was outlawed, giving perch stocks there some time to recover. Scientists had for some time assumed that this fishing ban would not affect the reproduction cycles of the perch quickly and that they were going to need a long time to revert back to the cycles they relied on before commercial fishing ever started. But new research led by scientists at Purdue University finds that maturation schedules of yellow perch in southern Lake Michigan are much more resilient than had been previously thought possible.

Read More