YSI 6820 V2-2 Multi-Parameter Water Quality Sonde Banner
6820V2-01

YSI 6820 V2-2 Multi-Parameter Water Quality Sonde

YSI 6820 V2-2 Multi-Parameter Water Quality Sonde

Description

The YSI 6820 V2-2 has (1) temperature/conductivity port, (1) pH/ORP port, (1) ISE port, and (2) optical ports.

Features

  • Perfect for multi-parameter spot sampling applications with the YSI 650 display unit
  • All sensors are field-replaceable, and optical sensors feature self-cleaning wipers
  • Compatible with NexSens real-time data logging systems
More Views
List Price
$$$$$
Your Price
Get Quote

Usually ships in 3-5 days
Shipping Information
Return Policy
Why Buy From Fondriest?

Details

The V2 sondes represent the new generation of multi-parameter sondes from YSI. Perfect for harsh fouling environments, YSI's next generation optical sensors feature an integrated wiper that prevents the impacts of biofouling, a corrosion-resistant titanium wiper shaft, and replaceable seals.

The YSI 6820 V2-2 sonde is powered by a YSI 650 display unit and is perfect for spot sampling applications.

The YSI 6820 V2-2 has the following available ports:

  • (1) Temperature/Conductivity
  • (1) pH or pH/ORP
  • (1) ISE (Nitrate, Ammonium, or Chloride)
  • (2) Optical (Dissolved Oxygen, Turbidity, Chlorophyll, Blue-Green Algae, and/or Rhodamine)
Notable Specifications:
  • Medium: Fresh, sea, or polluted water
  • Operating Temperature: -5 to +50 C
  • Storage Temperature: -10 to +60 C
  • Communications: RS-232, SDI-12
  • Software: EcoWatch
  • Diameter: 2.86" (7.3cm)
  • Length: 13.5" (34.3cm)
  • Weight: 3.4 lbs. (1.5kg)
  • External Power: 12 VDC
  • Warranty: 2 years
What's Included:
  • (1) YSI 6820 V2-2 sonde
  • (1) Temperature/conductivity sensor
  • (1) Soft-sided carrying case
  • (1) EcoWatch for Windows software CD
  • (1) Calibration cup
  • (1) Probe guard
  • (1) 6-Series operations manual
  • (1) Maintenance kit
Image Part # Product Description Price Stock Order
YSI 6820 V2-2 Multi-Parameter Water Quality Sonde 6820V2-01 6820 V2-2 Sonde with temperature/conductivity sensor Usually ships in 3-5 days
YSI 6820 V2-2 Multi-Parameter Water Quality Sonde 6820V2-02 6820 V2-2 Sonde with temperature/conductivity & shallow depth sensor
Usually ships in 3-5 days
YSI 6820 V2-2 Multi-Parameter Water Quality Sonde 6820V2-03 6820 V2-2 Sonde with temperature/conductivity & medium depth sensor
Usually ships in 3-5 days
YSI 6820 V2-2 Multi-Parameter Water Quality Sonde 6820V2-04 6820 V2-2 Sonde with temperature/conductivity & shallow vented level sensor
Usually ships in 3-5 days
Image Part # Product Description Price Stock Order
YSI 6561 pH Sensor 006561 6561 pH sensor In Stock
YSI 6565 pH/ORP Sensor 006565 6565 pH/ORP sensor In Stock
YSI 5564A Amplified pH Sensor 655564 5564A amplified pH sensor
$280.25
In Stock
YSI 5565A Amplified pH/ORP Sensor 655565 5565A amplified pH/ORP sensor
$370.50
In Stock
YSI 6150 ROX Dissolved Oxygen Sensor 606150 6150 ROX optical dissolved oxygen sensor with self-cleaning wiper Usually ships in 3-5 days
YSI 6136 Turbidity Sensor 606136 6136 turbidity sensor with self-cleaning wiper Usually ships in 3-5 days
YSI 6131 Blue-Green Algae Sensor 606131 6131 BGA (phycocyanin) sensor with self-cleaning wiper Usually ships in 3-5 days
YSI 6132 Blue-Green Algae Sensor 606132 6132 BGA (phycoerythrin) sensor with self-cleaning wiper Usually ships in 3-5 days
YSI 6025 Chlorophyll Sensor 606025 6025 chlorophyll sensor with self-cleaning wiper Usually ships in 3-5 days
YSI 6130 Rhodamine WT Sensor 006130 6130 Rhodamine WT sensor with self-cleaning wiper Usually ships in 3-5 days
YSI 6882 Chloride ISE Sensor 006882 6882 chloride sensor, for freshwater use only Usually ships in 3-5 days
YSI 6883 Ammonium ISE Sensor 006883 6883 ammonium sensor, for freshwater use only Usually ships in 3-5 days
YSI 6884 Nitrate ISE Sensor 006884 6884 nitrate sensor, for freshwater use only Usually ships in 3-5 days
NexSens MS8 to USB Adapter MS8-USB Female MS8 to USB adapter for power & communications to YSI 6-Series sondes
$295.00
Usually ships in 3-5 days
YSI 6095B PC Adapter 006095 6095B PC adapter, DB9 to MS8 (field cable) & MS4 (power)
$195.00
In Stock
YSI 6067B Calibration Cable 006067 6067B lab PC interface & calibration cable, 10 ft.
$235.00
Usually ships in 3-5 days
YSI 6038 Power Supply 006038 6038 power supply, 12 VDC, 110 VAC input, MS4 connector
$70.00
Usually ships in 3-5 days
YSI 650 MDS Multi-Parameter Display System 650-01 650 Multi-parameter display, standard memory Usually ships in 3-5 days
YSI 650 MDS Multi-Parameter Display System 650-02 650 Multi-parameter display, high memory Usually ships in 3-5 days
YSI 650 MDS Multi-Parameter Display System 650-03 650 Multi-parameter display with barometer, standard memory Usually ships in 3-5 days
YSI 650 MDS Multi-Parameter Display System 650-04 650 Multi-parameter display with barometer, high memory Usually ships in 3-5 days
YSI 6-Series Sonde Field Cables 006090 6090 field cable, 8 ft. In Stock
YSI 6-Series Sonde Field Cables 006091 6091 field cable, 25 ft. In Stock
YSI 6-Series Sonde Field Cables 006092 6092 field cable, 50 ft. In Stock
YSI 6-Series Sonde Field Cables 006093 6093 field cable, 100 ft. In Stock
YSI 6-Series Sonde Vented Field Cables 063380 6195 vented field cable, 10 ft. Usually ships in 3-5 days
YSI 6-Series Sonde Vented Field Cables 006191 6191 vented field cable, 25 ft. Usually ships in 3-5 days
YSI 6-Series Sonde Vented Field Cables 006192 6192 vented field cable, 50 ft. Usually ships in 3-5 days
YSI 6-Series Sonde Vented Field Cables 006193 6193 vented field cable, 100 ft. Usually ships in 3-5 days
YSI 6096 Flying Lead Cable Adapters 006096 6096 flying lead cable adapter, MS8 (field cable) to flying leads, 15 ft.
$150.00
In Stock
YSI 6096 Flying Lead Cable Adapters SP6096X-1 6096 flying lead cable adapter, MS8 (field cable) to flying leads, 50 ft.
$220.00
Usually ships in 3-5 days
NexSens A50-S YSI 6-Series Sonde Junction Box A50-S Junction box for YSI 6-Series sondes, includes MS8 connector and gland fitting
$249.00
Usually ships in 3-5 days
YSI 6108 Desiccant Cartridge Kit 006108 6108 desiccant cartridge kit, 2 pack
$130.00
Usually ships in 3-5 days
YSI 6109 Desiccant Canister Kit 006109 6109 desiccant canister kit, for use with long-term vented level monitoring
$270.00
Usually ships in 3-5 days
YSI 6160 Flow Cell 606160 6160 flow cell, for use with YSI 6820 & 6920
$360.00
In Stock
YSI Anti-Fouling C-Spray Protective Probe Solution 616290 C-SPRAY protective probe solution, 100mL
$30.00
Usually ships in 3-5 days
YSI Anti-Fouling Sensor Screens 616270 Anti-fouling screen kit, pack of 2
$40.00
In Stock
YSI 6189-AF Anti-Fouling Copper Tape 616189 6189-AF anti-fouling copper tape kit
$70.00
In Stock
YSI 6176-AF Anti-Fouling Sonde Guard Kit 616176 6176-AF anti-fouling sonde guard kit, 6820/6920
$850.00
Usually ships in 3-5 days
YSI 6182 Zinc Anode Kit 006182 6182 zinc anode kit
$50.00
Usually ships in 3-5 days
YSI 6885 Sonde Weight Kit 006885 6885 sonde weight kit, 2 lbs., for use with YSI 6820 & 6920
$140.00
Usually ships in 3-5 days
YSI 6124 Instrument Backpack 655108 6124 backpack, for use with YSI 6-series instruments
$190.00
Usually ships in 3-5 days
YSI 6930 Hard-Sided Pelican Carrying Case 606930 6930 hard-sided black Pelican carrying case for 6-Series & 556 meters
$318.25
Usually ships in 3-5 days
YSI 6945 Mooring Clamp for 6920 Sonde 6945 Mooring clamp, 6920 series sondes
$500.00
In Stock
NexSens Deployment Pipe Assemblies 914 Deployment pipe assembly with dual eye bolts, 4" schedule 80 PVC, 32" length
$195.00
Usually ships in 3-5 days
NexSens Deployment Pipe Assemblies 914M Deployment pipe assembly with stop bolt & threaded male adapter, 4" schedule 80 PVC, 32" length
$195.00
Usually ships in 3-5 days

Questions & Answers

| Ask a Question
I'm getting an "out of range" message, what does this mean?
Normally an "out of range" message means the pH probe has a bad slope. A pH probe with a bad slope needs to be cleaned and reconditioned.
Can I calibrate with Formazin?
Yes, but the calibration needs to be completed within 2 minutes or settling can cause a change in standard value.
I'm having trouble calibrating my ISE sensors.
A common problem when calibrating ISE sensors is forgetting that the pH and temperature probes need to be in solution during calibration.

Related Products

In The News

Six-year study tackles nonpoint source pollution in Louisiana watershed

An intensive 6-year water quality study of an agricultural watershed in Louisiana should give managers there a leg up in tackling nonpoint source pollution along the Bayou Plaquemine Brule. Land-use in the bayou's watershed is 89 percent agricultural, producing rice, soybeans, sugarcane and crawfish. Degradation from the runoff landed the slow-moving river on the state's list of impaired waters in 1998. In an effort to better understand water quality issues in the basin, Durga Poudel led a comprehensive data collection campaign throughout the watershed from 2002 to 2008. Poudel, professor and assistant director of the School of Geosciences at the University of Louisiana at Lafayette, said he went into the study hoping to answer the questions facing managers in any impaired watershed.

Read More

Bottom Composition Matters, Underwater Cameras Can Help

As a pro angler, I use my Lowrance electronics every single time I am on the water. They are great at locating fish and structure, but when combined with my FishSens SondeCAM HD Underwater Camera they can show everything. A camera is a great tool for someone who wants to better understand what they are seeing on their electronics and for me, it helps get a clear picture of one of the most important things in bass fishing: bottom composition. Hard Spots Hard bottoms are usually the best, and bass will relate to hard bottoms of different types depending on the region. My Lowrance StructureScan will show hard bottoms as bright, white areas on the screen where softer bottoms will be more grayish.

Read More

Targeting Spawning Bass: Are They Going to Bite?

This time of year, anglers all over are fishing for bass they can see in the shallows. Some bass will be easy to catch and some are nearly impossible, like those that are in the act of spawning instead of just guarding their beds. There are a few things that I do to determine if the fish is going to bite and if they are worth spending time fishing for. Locating Bedding Bass One of the best ways to find bedding bass is to cruise the shallows with your trolling motor at about 40 or 50%. I have found that this is the best speed to both cover water and avoid spooking fish. Anything faster will scare fish away long before you get to them.

Read More