Thermo Orion Star A222 Portable Conductivity Meter

The Thermo Orion Star A222 portable conductivity meter allows accurate conductivity data to be recorded in any setting.

Features

  • Displays conductivity, TDS, salinity, resistivity and temperature readings using Orion electrodes
  • AUTO-READ function alerts user and locks stable readings on backlit LCD screen
  • USB and RS-232 ports allow easy data transfer of up to 1000 time-stamped data points
List Price $858.00
Your Price $772.20
Usually ships in 3-5 days
Thermo Scientific
Government and Educational PricingGovernment and Educational Pricing
Free Lifetime Tech SupportFree Lifetime Tech Support
Free Ground ShippingFree Ground Shipping
ImagePart#Product DescriptionPriceStockOrder
Thermo Orion Star A222 Portable Conductivity MeterSTARA2220 Orion Star A222 Conductivity Portable Meter
$772.20
Usually ships in 3-5 days
Thermo Orion Star A222 Portable Conductivity Meter Kit STARA2225 Orion Star A222 Conductivity Portable Meter Kit
$1,214.10
Usually ships in 3-5 days
ImagePart#Product DescriptionPriceStockOrder
Thermo Orion Star A-Series Hard Carrying Case STARA-CS Orion Star A-series portable hard field case
$135.90
Usually ships in 3-5 days
Thermo Orion Star A-Series Soft Carrying Case 1210005 Orion Star A-series portable soft field case
$143.10
Usually ships in 3-5 days
Thermo Orion Star A-Series Armor STARA-AR Orion Star A-series portable meter armor
$99.00
Usually ships in 3-5 days
Thermo Orion Star A-Series Conductivity and DO Probe Holder STARA-ESCD Orion Star A-series conductivity and DO probe holder for use with armor
$27.27
Usually ships in 3-5 days
Thermo Orion DuraProbe 4-Electrode Conductivity Cell 013005MD Orion DuraProbe 4-electrode conductivity cell, MiniDIN connector, 1.5m cable
$521.10
Usually ships in 3-5 days
Thermo Orion 4-Electrode Conductivity Cell 013010MD Orion DuraProbe 4-electrode conductivity cell, MiniDIN connector, 3m cable
$564.30
Usually ships in 3-5 days
Thermo Orion 4-Electrode Conductivity Cell 013020MD Orion DuraProbe 4-electrode conductivity cell, MiniDIN connector, 6m cable
$635.40
Usually ships in 3-5 days
Thermo Orion 4-Electrode Conductivity Cell 013025MD Orion DuraProbe 4-electrode conductivity cell, MiniDIN connector, 10m cable
$732.60
Usually ships in 3-5 days
Thermo Orion Star Meter Universal Power Adapter 1010003 Orion universal power adapter for Star meters
$63.72
Usually ships in 3-5 days
Thermo Orion 60mL Conductivity Standards 011008 Orion conductivity standard, 100 uS, (5) 60mL bottles
$98.10
Usually ships in 3-5 days
Thermo Orion 1413 µS Conductivity Standard Pouches 01100710 Orion conductivity standard, 1413 uS/cm, (10) 15mL pouches
$40.23
Usually ships in 3-5 days
Thermo Orion 12,900 µS Conductivity Standard Pouches 01100610 Orion conductivity standard, 12,900 uS/cm, (10) 15mL pouches
$40.23
Usually ships in 3-5 days
Thermo Orion Electrode Rinse Pouches 911110 Orion electrode rinse, (10) individual pouches
$31.86
Usually ships in 3-5 days
Thermo Orion Conductivity Calibration Resistor Kit 1010001 Orion conductivity calibration resistor kit, MiniDIN connector
$417.60
Usually ships in 3-5 days

The waterproof, battery-operated Thermo Orion Star A222 portable conductivity meter stands up to the most demanding field applications and delivers over 800 hours of continuous operation. The meter can be calibrated manually or automatically using Thermo conductivity standards to make the setup process easy. It comes equipped with a large storage capacity for time-stamped data points, which can be conveniently uploaded to a PC through the meter's USB and RS-232 ports.

The rugged, user-friendly meter displays conductivity, TDS, salinity, resistivity and temperature readings on a large, backlit LCD screen, while icons provide quick updates on battery life, electrode status and calibration information. Simple button layout and on-screen messages simplify calibration and explain setup menu choices.

 

  • AUTO-READ function to alert user and lock on-screen readings when stable
  • Selectable cell constant for use with 2- or 4-cell conductivity cells
  • Selectable reading reference temperatures of 15, 20 or 25 C to increase accuracy
  • Includes standard practical salinity curve for salinity readings, linear or ISO/EN 27888 curves for TDS
  • Non-volatile memory holds up to 1000 data points
  • Electrode arm and newly-designed probe holder to place probes into samples
  • Universal power supply or battery power option
  • USB and RS-232 ports to upload data and update included data analysis software
  • Multilanguage interface supports English, Spanish, French, Italian, German and Chinese
  • IP67-rated housing (may be immersed for up to one hour with no water incursion)
  • 3 year meter warranty
  • Conductivity
  • Range: 0.001 uS to 3000 mS
  • Resolution: Min 0.001 uS or 4 significant figures
  • Relative Accuracy: 0.5% reading +/-1 digit
  • Reference: 15, 20, 25 C (default)
  • Compensation: Linear (0.0 to 10.0 %/C)
  • Compatible Cell Constants: 0.001 to 199.9
  • Number of Calibration Points: Up to 5
  • Calibration Editing: Yes
  • Resistivity
  • Range: 2 ohm to 100 meg-ohm
  • Resolution: 2 ohm-cm
  • Relative Accuracy: 0.5% reading +/-1 digit
  • Salinity
  • Type: Practical salinity
  • Range: 0.01 to 80.0 ppt NaCl equivalent; 0.01 to 42 ppt practical
  • Resolution: 0.01
  • Relative Accuracy: +/-0.1
  • TDS
  • Range: 1 to 200 ppt
  • Resolution: 4 significant figures
  • Relative Accuracy: 0.5% reading +/-1 digit
  • TDS Factor Range: Linear 0.01 to 10.00
  • Temperature
  • Range: -5 to 105 C
  • Resolution: 0.1
  • Relative Accuracy: +/-0.1 C
  • Offset Calibration: 1 point
  • Datalogging
  • Number of Points: 1000 with time and date stamp
  • Log Function: Manual, Automatic with AUTO-READ
  • Log Edit: Delete last reading or all
  • General
  • Display: Backlit LCD
  • Inputs: 8-pin mini-DIN
  • Outputs: RS-232, USB
  • Power Adapter: Universal AC, 100-240 VAC
  • Battery Power: 4 AAs, 800 hrs life
  • Environmental Requirements: 5 to 45 C and 5 to 85% relative humidity, non-condensing
  • Regulatory and Safety: CE, TUV 3-1, FCC Class A
  • IP Rating: IP67, waterproof
  • Warranty: 36 months (from date of purchase)
Questions & Answers
No Questions
Please, mind that only logged in users can submit questions

In The News

Choosing The Right Thermo Portable For Your Project

With so many options in Thermo Scientific’s Orion Star A line, it can be difficult to narrow down which meter will best fulfill a project’s needs. One easy way to rule out some meters is by considering application type. For projects that rely largely on collecting samples in the field, a portable meter is clearly the way to go. But there’s still a handful of meters to choose from. To simplify making the right choice, we spoke with Ricki Hartwell, the global product manager for Thermo Scientific’s Orion Laboratory and Field Instruments. She recently shared her tips on choosing the right Thermo benchtop . Let’s take a look at her recommendations for selecting the right portable meter.

Read More

Birds, Fish and Shifting Sediment; How Lake Erie Buoys Measure It All

Since its population bottomed out, the federally-endangered Piping Plover in the Great Lakes has made a comeback for the ages.  A population that once measured approximately 17 pairs and rebounded, hitting 76 pairs in 2017. The same year that count was made, the plovers had also returned to Gull Point, a nesting location that hadn’t been used in more than 60 years.   In an effort to understand some of the conditions that have allowed this species to return to its habitat, researchers have directed their attention toward a curious instrument for help. A buoy that floats off the coast of Presque Isle State Park , near where Gull Point is located.

Read More

Much remains unknown about sharks. The Cal State Shark Lab wants to change that

Thirty years ago, white shark sightings near California’s beaches almost never happened. For Chris Lowe, who was a graduate student at California State University’s Shark Lab at the time, spying a dorsal fin from one of the ocean’s top predators was very rare. Prior to the mid-90’s, an expansive commercial fishing operation and the loss of marine animals decimated white shark populations. If their food wasn’t being hunted, sharks were getting caught in gill nets. At that point, they would be killed anyways before getting brought to the market to be sold. Then in 1994, California residents approved propositions that banned gillnets in state waters and enacted protections for the white shark.