YSI 5100 Benchtop Dissolved Oxygen Meter Banner
051004

YSI 5100 Benchtop Dissolved Oxygen Meter

YSI 5100 Benchtop Dissolved Oxygen Meter

Description

The 5100 has built-in SOUR (Specific Oxygen Uptake Rate) software to meet US EPA regulations.

Features

  • Internal memory for 100 datasets with RS-232 interface for direct upload to PC
  • Easy compliance with USEPA 503 regulations with built-in SOUR/OUR software
  • Compatible with YSI BOD software, making BOD calculations simple
Free Shipping on this product
List Price
$1810.00
Your Price
$1,719.50
Usually ships in 3-5 days

Shipping Information
Return Policy
Why Buy From Fondriest?

Details

The YSI 5000 Series saves time and increases efficiency with features such as auto calibration, large graphic display, and low-profile keypad. Microprocessor-based, YSI 5000 instruments will store 100 sets of data and are equipped with RS-232 interface for direct link to your computer. To make BOD measurements even easier, BOD Analyst software (5120) can also be purchased. The YSI 5000 Series is user upgradeable through the YSI web site, making it easy to take advantage of future software improvements.

The full-featured YSI 5100 instrument offers even greater performance and flexibility with auto calibration, an internal barometer, and built-in SOUR software to meet U.S. EPA 503 regulations for safe use of biosolids. OUR (Oxygen Uptake Rate) and SOUR (Specific Oxygen Uptake Rate) are also valuable process control tools because they indicate the biological activity of microorganisms used in treatment. The YSI 5100 can also be used with a barcode scanner, eliminating the need to manually maintain bench sheets. These tools greatly reduce the labor required for processing BODs and calculating BOD values.
What's Included:
  • (1) Lab dissolved oxygen meter
  • (1) Power supply
  • (1) Operations manual
Image Part # Product Description Price Stock Order
YSI 5100 Benchtop Dissolved Oxygen Meter 051004 5100 benchtop dissolved oxygen meter with SOUR software, 115VAC (cable/sensor sold separately)
$1719.50
Usually ships in 3-5 days
YSI 5100 Benchtop Dissolved Oxygen Meter 051005 5100 benchtop dissolved oxygen meter with SOUR software, 230VAC (cable/sensor sold separately)
$1900.00
Usually ships in 3-5 days
Image Part # Product Description Price Stock Order
YSI BOD Analyst Pro Software 625120 5120 BOD Analyst Pro software
$565.25
Usually ships in 3-5 days
YSI 5010 BOD Probe 050102 5010 BOD probe, self-stirring, 5' cable
$665.00
Usually ships in 3-5 days
YSI 5010-W Wine Bottle BOD Probe 050113 5010-W wine bottle BOD probe, self-stirring, 5' cable
$1273.00
Usually ships in 3-5 days
YSI 5015 Barcode Scanner 051060 5015 bar code scanner
$926.25
Usually ships in 3-5 days
YSI 059160 BOD bottle bar code labels, 1000 labels
$152.00
Usually ships in 3-5 days

Questions & Answers

| Ask a Question
How do I adjust for barometric pressure?
The YSI 5100 Benchtop DO meter features an internal barometer, eliminating the need for an external barometer or look-up chart.
Is there an easy way to enter data?
In addition to its keypad with audio and tactile response, the 5100 Benchtop DO meter features a port for a computer keyboard, allowing quick data entry. The meter also features bar-code scanning capability.

Related Products

In The News

No Evidence of Natural Gas From Fracking In Ohio Drinking Water

A recent study of Appalachian Ohio drinking water from private wells found no evidence of natural gas contamination from “fracking” (drilling for oil and gas) despite concerns about the practice. University of Cincinnati geologists investigated drinking water in Carroll, Harrison, and Stark counties, a rural area in the northeast portion of the state, where private underground wells are the only source of drinking water for many residents. Associate professor of geology Amy Townsend-Small described the time-series study, which is the first to measure sources and concentrations of methane in the fracking region of Ohio, to EM.

Read More

Sedimentation Research Helps Determine Effects of Seabed Mining

Scientists from New Zealand's National Institute of Water and Atmospheric Research, NIWA , are engaging in sedimentation research to help determine the effects of seabed mining and fishing on the environment. This work represents some of the most challenging underwater research ever undertaken by the NIWA team. The need for the work arises from the controversy surrounding proposed seabed ventures—each of which was met with serious opposition based on presumed environmental effects such as drifting sediment plumes. In an effort to determine the full environmental impacts of such seabed activities, the NIWA team has undertaken an unusual project deploying high-tech instruments on the ocean floor. NIWA principal scientist and voyage leader Dr.

Read More

Marine Protected Areas Cannot Tolerate Climate Change

Marine Protected Areas (MPAs) are traditionally a haven for marine fauna under threat from human activities. However, new research confirms that greenhouse gases will continue to warm the world's oceans and reduce their oxygen concentrations, rendering most existing MPAs uninhabitable by 2100. John Bruno , the study’s lead author , is a marine ecologist and biology professor in the College of Arts and Sciences at UNC-Chapel Hill. Dr.

Read More