YSI 6883 Ammonium ISE Sensor
Features
- Freshwater use only
- Best for sampling applications
- Field-replaceable
- Expedited repair and warranty service
- Lifetime technical support
- More
Overview
The YSI 6883 ammonium ISE sensor employs a silver/silver chloride (Ag/AgCl) wire electrode in a custom-filling solution. Nonactin membrane separates the internal solution from the sample medium, and this membrane selectively interacts with ammonium ions.
Mechanics
When the probe is immersed in water, a potential is established across the membrane that depends on the relative amounts of ammonium in the sample and the internal filling solution. This potential is read relative to the reference electrode of the sonde pH probe. As for all ISEs, there is a linear relationship between the logarithm of the ammonium activity (or concentration in dilute solution) and the observed voltage. The Nernst equation describes this relationship.
- Range: 0 to 200 mg/L-N
- Resolution: 0.001 to 1 mg/L-N (range dependent)
- Accuracy: +/-10% of reading or 2 mg/L, whichever is greater
- Warranty: 6 months
In The News
Data-Driven Decisions: Tracking Sediment during the Klamath Dam Removal
The largest dam removal in U.S. history, the deconstruction of the Klamath Dam is slated to begin this summer. The project includes four dams along the Klamath River with the first and smallest dam, Copco #2, scheduled for removal first. As each of the dams are torn down, scientists and consultants will keep a close eye on the state of the Klamath River downstream to assess the impact of undamming the river. 
 
Shawn Hinz, managing partner and environmental toxicologist with Gravity Consulting , has been involved with the Klamath Dam project for over a decade. Hinz was a part of these earlier steps, representing the academic stakeholder position as a graduate student sitting on a board of other stakeholders.
Read MoreFrom the Tap: Source Water Monitoring for Public Health
In regions with historically secure access to clean drinking water, few think about the work that goes into ensuring that the water they fill their cups with is safe. In reality, millions of dollars are invested in the infrastructure, equipment and teams involved in converting source water into drinking water. 
 
While all the work that goes into providing clean water often goes unnoticed, analysts like Michele Gilkerson, a water research analyst with the City of Columbus Division of Water, know exactly how much goes into securing safe water for millions of people. 
 
Gilkerson started with Battelle Memorial Institute in 1991 in their water ecology section. There, she saw how interesting source water monitoring could be, even though it isn’t often spotlighted in the environmental sector.
Read MoreChoosing the Right Water Quality Monitoring Systems Is Crucial for Stantec Inc.
Data is king when it comes to water quality monitoring. It is not merely the type of data being collected that matters but also how that data is stored, processed and presented. When Joseph Kamalesh, a project manager with Stantec Consulting Services Inc. , needs to find the right equipment for large client-based projects, he knows to keep these factors in mind. 
 
Joseph has a background in water quality and water flow monitoring instrumentation, which he continues to focus on at Stantec. During college and his early career, Joseph gained experience with water instrumentation, consisting primarily of on-site wastewater sampling and sampling small systems.
Read More