HOBO H22 Energy Data Logger
- Free ground shipping
- Expedited repair and warranty service
- Lifetime technical support
- More
- Record up to 15 channels
- Provides 12V excitation for third-party sensors
- Flexible power options
Overview
The HOBO H22 Energy Logger is a modular 15-channel data logger designed for energy and facility managers to monitor energy usage and industrial equipment. With this device, users can quickly and easily identify various issues related to HVAC systems, machinery, and other equipment, allowing them to address problems promptly.
The H22 logger is compatible with a range of pre-defined plug-and-play smart sensors. When combined with the logger, these sensors create a robust monitoring system that works seamlessly with HOBOware software.
Note: External sensors are sold separately. Requires HOBOware software and interface cables.
|
Operating range |
-20° to 50°C with alkaline batteries -4° to 122°F with alkaline batteries
-40° to 60°C with lithium batteries -40° to 140°F with lithium batteries |
|
Sensor inputs
|
Three FlexSmart multi-channel modules and up to 6 Smart Sensors (which may have multiple parameters/channels) |
|
Sensor connectors |
Six RJ-12 Smart Sensor jacks plus 3 FlexSmart module slots |
|
Communication |
RS-232 via 3.5 mm serial port or/and 9-pin D-Sub connector |
|
Dimensions |
15.6 cm x 8.4 cm x 4.6 cm 6.13" x 3.31" x 1.81" |
|
Weight |
435 g with batteries 15.23 oz with batteries
238 g without batteries 8.33 oz without batteries |
|
Memory |
512K nonvolatile flash data storage |
|
Memory modes |
Stop when full; wrap when full |
|
Operational indicators |
Six indicators provide logging and sensor network status |
|
Logging interval |
One second to 18 hours, user-specified interval (2-second minimum for two-channel S-FS-TRMSA operation) |
|
Sensor excitation |
12 V DC at 200 mA total, with user-programmable warmup time on a per-channel basis |
|
Battery life |
One year typical use (up to 75 mA excitation with 10-minute or longer logging Interval and 1-second warmup time) |
|
Battery type |
Eight standard AA alkaline batteries included (for operating conditions -20°C to 50°C) Eight standard AA alkaline batteries included (for operating conditions -4°F to 122°F)
Optional AA lithium batteries available for operating conditions of -40° to 60°C. Optional AA lithium batteries available for operating conditions of -40° to 140°F. |
|
External power |
Supports optional 13.6 V DC regulated AC Wall Adapter Connector. Internal batteries may remain installed. Alternatively, an automotive battery or 9-12 V DC regulated Wall Adapter may be used, but it is recommended to remove the internal batteries since they will discharge to the level of the external supply. |
|
Time accuracy |
0 to 2 seconds for the first data point and ±5 seconds per week at 25°C 0 to 2 seconds for the first data point and ±5 seconds per week at 77°F |
|
Logging mode |
Immediate, timed delay, or trigger (button-push) start options; supports sampling intervals for some sensors |
|
Data communication |
Current readings while logging; read out while logging; read out when stopped |
- HOBO H22-001 Energy Logger
- Eight 1.5V alkaline batteries
- 1 miniature slotted screwdriver
- Blank label
- Rubber feet
- Record up to 15 channels
- Provides 12V excitation for third-party sensors
- Flexible power options
Overview
The HOBO H22 Energy Logger is a modular 15-channel data logger designed for energy and facility managers to monitor energy usage and industrial equipment. With this device, users can quickly and easily identify various issues related to HVAC systems, machinery, and other equipment, allowing them to address problems promptly.
The H22 logger is compatible with a range of pre-defined plug-and-play smart sensors. When combined with the logger, these sensors create a robust monitoring system that works seamlessly with HOBOware software.
Note: External sensors are sold separately. Requires HOBOware software and interface cables.
|
Operating range |
-20° to 50°C with alkaline batteries -4° to 122°F with alkaline batteries
-40° to 60°C with lithium batteries -40° to 140°F with lithium batteries |
|
Sensor inputs
|
Three FlexSmart multi-channel modules and up to 6 Smart Sensors (which may have multiple parameters/channels) |
|
Sensor connectors |
Six RJ-12 Smart Sensor jacks plus 3 FlexSmart module slots |
|
Communication |
RS-232 via 3.5 mm serial port or/and 9-pin D-Sub connector |
|
Dimensions |
15.6 cm x 8.4 cm x 4.6 cm 6.13" x 3.31" x 1.81" |
|
Weight |
435 g with batteries 15.23 oz with batteries
238 g without batteries 8.33 oz without batteries |
|
Memory |
512K nonvolatile flash data storage |
|
Memory modes |
Stop when full; wrap when full |
|
Operational indicators |
Six indicators provide logging and sensor network status |
|
Logging interval |
One second to 18 hours, user-specified interval (2-second minimum for two-channel S-FS-TRMSA operation) |
|
Sensor excitation |
12 V DC at 200 mA total, with user-programmable warmup time on a per-channel basis |
|
Battery life |
One year typical use (up to 75 mA excitation with 10-minute or longer logging Interval and 1-second warmup time) |
|
Battery type |
Eight standard AA alkaline batteries included (for operating conditions -20°C to 50°C) Eight standard AA alkaline batteries included (for operating conditions -4°F to 122°F)
Optional AA lithium batteries available for operating conditions of -40° to 60°C. Optional AA lithium batteries available for operating conditions of -40° to 140°F. |
|
External power |
Supports optional 13.6 V DC regulated AC Wall Adapter Connector. Internal batteries may remain installed. Alternatively, an automotive battery or 9-12 V DC regulated Wall Adapter may be used, but it is recommended to remove the internal batteries since they will discharge to the level of the external supply. |
|
Time accuracy |
0 to 2 seconds for the first data point and ±5 seconds per week at 25°C 0 to 2 seconds for the first data point and ±5 seconds per week at 77°F |
|
Logging mode |
Immediate, timed delay, or trigger (button-push) start options; supports sampling intervals for some sensors |
|
Data communication |
Current readings while logging; read out while logging; read out when stopped |
- HOBO H22-001 Energy Logger
- Eight 1.5V alkaline batteries
- 1 miniature slotted screwdriver
- Blank label
- Rubber feet